Details

TeifsWeatherTight VNT

The following details can be downloaded directly from Teifs in Autocad .DWG format. Simply click on the desired file and you will be prompted by your browser for file saving instructions.

 

Content Download Download Zip
Complete Teifs System Details
  • All Details
PDF DWG
General Construction
  • VNT G1.01 - Teifs WeatherTight VNT System Components
PDF DWG
General Construction
  • VNT G1.02 - Weathertight VNT Framed Wall Application
PDF DWG
General Construction
  • VNT G1.03A - Rough Opening Flashing Procedure 1 of 2
PDF DWG
General Construction
  • VNT G1.03B - Rough Opening Flashing Procedure 2 of 2
PDF DWG
General Construction
  • VNT G1.04 - Preliminary Mesh Application
PDF DWG
General Construction
  • VNT G1.05 - Inside and Outside Corners
PDF DWG
Expansion Joints
  • VNT E1.01 - Inside Corner Termination
PDF DWG
Expansion Joints
  • VNT E1.02 - Through-System Flashing with Weeps
PDF DWG
Expansion Joints
  • VNT E1.03 - Expansion Joint at Dissimilar Substrates
PDF DWG
Expansion Joints
  • VNT E1.04A - Floor Line Deflection Slip Joint (2D)
PDF DWG
Expansion Joints
  • VNT E1.04B - Floor Line Expansion (ISO)
PDF DWG
Expansion Joints
  • VNT E1.05A - Expansion Joint with Flashing at Floor (2D)
PDF DWG
Expansion Joints
  • VNT E1.05B - Expansion Joint with Flashing at Floor (ISO)
PDF DWG
Expansion Joints
  • VNT E1.06A - Vertical Expansion Joint (2D)
PDF DWG
Expansion Joints
  • VNT E1.06B - Vertical Expansion Joint(ISO)
PDF DWG
Expansion Joints
  • VNT E1.07 Horizontal Expansion Joint
PDF DWG
Terminations
  • VNT T1.01A - Termination Above Foundation (Vented Track)
PDF DWG
Terminations
  • VNT T1.01B - Termination Above Foundation (Backwrapped)
PDF DWG
Terminations
  • VNT T1.02 - Termination At Grade
PDF DWG
Terminations
  • VNT T1.03A - Cladding Transition (2D)
PDF DWG
Terminations
  • VNT T1.03B - Cladding Transition (ISO)
PDF DWG
Terminations
  • VNT T1.04 - System Termination at ADA Sidewalk
PDF DWG
Terminations
  • VNT 1.05 - Termination at Balcony Slab
PDF DWG
Windows
  • VNT W1.01 - Head Assembly (Window, Door, Louver Vents, Etc)
PDF DWG
Windows
  • VNT W1.02 - Termination at Window Head
PDF DWG
Windows
  • VNT W1.03A - Termination at Metal Flashed Window Sill (2D)
PDF DWG
Windows
  • VNT W1.03B - Termination at Metal Flashed Window Sill (ISO)
PDF DWG
Windows
  • VNT W1.04 - Termination at Window Jamb
PDF DWG
Windows
  • VNT W1.05 - Termination at Finned Window Head
PDF DWG
Windows
  • VNT W1.06 - Termination at Finned Window Sill
PDF DWG
Windows
  • VNT W1.07 - Termination at Finned Window Jamb
PDF DWG
Roof Line
  • VNT R1.01A - Termination at Box Cornice (2D)
PDF DWG
Roof Line
  • VNT R1.01B - Termination at Box Cornice (ISO)
PDF DWG
Roof Line
  • VNT R1.02A - Termination at Soffit With Insulation
PDF DWG
Roof Line
  • VNT R1.02B - Termination at Soffit Without Insulation
PDF DWG
Roof Line
  • VNT R1.03 - Parapet Wall Termination at Cap Flashing
PDF DWG
Roof Line
  • VNT R1.04 - Termination at Gravel Stop
PDF DWG
Roof Line
  • VNT R1.05 - Intersection of Roof Cornice at System Wall
PDF DWG
Roof Line
  • VNT R1.06 - Termination at Roof
PDF DWG
Penetrations
  • VNT P1.01 - Fixture Attachment (by others)
PDF DWG
Penetrations
  • VNT P1.02 - Hose Bib (by others)
PDF DWG
Penetrations
  • VNT P1.03 - Downspout Attachment (by others)
PDF DWG
Penetrations
  • VNT P1.04 - Termination at Appliance Sleeve (by others)
PDF DWG
Penetrations
  • VNT P1.05 - Termination at Small Electrical Feature (by others)
PDF DWG
Penetrations
  • VNT P1.06 - Deck Attachment (by others)
PDF DWG
Penetrations
  • VNT P1.07 - Handrail Attachment (by others)
PDF DWG
Aesthetic Features
  • VNT A1.01 - Aesthetic Band and Groove
PDF DWG

 

 

Disclaimer: The design specifications and construction of the wall shall comply with all building codes and standards. Parex USA installation guidelines are for general information and guidance only and Parex USA specifically disclaims all liability for the use of this design, for design engineering, and for workmanship of any project. The wall assembly shall be designed to prevent condensation within the assembly. The designer and the user shall provide final drawings and specifications.

 

The drawings and any related notes or text contained thereon, are based upon typical requirements of Teifs exterior insulation and finish systems and are published strictly as a guide for architectural and construction industry professionals to illustrate typical or general design conditions.

 

These details are not to be used by themselves, and do not constitute design instructions for Teifs EIFS application. These details must be used in conjunction with Teifs current product specifications, product data sheets, and application instructions.

 

Any details shown are strictly for the purpose of illustrating typical Teifs EIFS. Any other materials shown in any details are incidental to the details, and are included only for clarity of the Teifs EIFS. Please consult with the manufacturers and/or suppliers of any separate materials for their product specifications and applications instructions.

 

Where site or design conditions not shown in these details are present, or any unusual design is involved, please consult with the Parex USA Technical Department for assistance.

 

PAREX USA DOES NOT WARRANT THE FITNESS OF SUITABILITY OF THESE DETAILS FOR CONSTRUCTION, OR ASSUME ANY LIABILITY FOR USE OF THESE DETAILS. IT IS THE SOLE RESPONSIBILITY OF ANY ARCHITECTURAL OR CONSTRUCTION INDUSTRY PROFESSIONAL TO APPLY THEIR PROFESSIONAL KNOWLEDGE IN UTILIZING THE INFORMATION CONTAINED IN THESE DETAILS.